A steel structure order is not a catalogue purchase. The steel is cut, drilled, welded and coated to your project’s drawings, so the questions that decide the outcome are not about price per tonne. They are about who is responsible for which part of the design, who approves the drawings, and how the corrosion protection is specified and proven.
This guide covers those points for buyers sourcing steel structures from China. It is written for contractors, developers and engineers, not for factories.

1. Settle design responsibility before you request quotes
In UK practice, as described in the guidance of the British Constructional Steelwork Association (BCSA), the engineer is typically responsible for structural analysis, overall stability and design of the primary members, while the steelwork contractor is responsible for connection design, secondary steelwork and coordination with other trades (summary of BCSA guidance). Other markets split this differently. The risk is the same everywhere: a gap that nobody owns.
When you source from China, write down for each item who is responsible:
- Primary beams and columns
- Connections and base plates
- Secondary steel, purlins and bracing
- Temporary works and erection method
- Interface with cladding, foundations and anchor bolts
If the factory is to design connections, ask for the calculation basis and who signs it. If your engineer does it, the factory should receive connection details with the drawings. Never leave this to a quote line such as “design included”.
2. Approve shop drawings, not just the concept
Shop drawings and the cutting list are where a mismatch is cheapest to find. Before fabrication starts, require:
- Shop drawings with member marks that match your structural drawings
- A cutting list and bill of materials with steel grade per member
- Bolt, weld and surface-treatment notes
- Your written approval, with changes logged
Our guide on how to write a material list or BOQ that Chinese factories can quote shows how to describe items so the quote and the drawings agree.
3. Specify the galvanising standard by name
“Galvanised” is not a specification. For fabricated steelwork dipped after fabrication, the international standard is ISO 1461:2022. It covers general properties and test methods for hot dip galvanized coatings on fabricated iron and steel articles. It does not cover continuously galvanized sheet or wire, tube galvanized in automatic plants, or products with their own standards such as fasteners, and it does not cover paint or other coatings applied over the galvanizing.
In the US, specifications reference ASTM A123 for steel products and ASTM A153 for hardware, as listed by the American Galvanizers Association. Pick the standard your project specification already names and write it into the order, together with the coating requirement from your engineer. Do not accept a thickness figure from a quote without the standard behind it.
Two practical points:
- Design for galvanising. Venting and drain holes and avoiding trapped sections are design items, and should be on the shop drawings.
- Steel chemistry. Silicon content affects coating thickness and brittleness, so ask for the mill certificate before the steel is dipped (SteelConstruction.info guidance note).
4. Verify certificates, not just receive them
For a steel order, the documents that matter are:
| Document | What to check |
|---|---|
| Mill certificate | Grade and heat number match the steel delivered |
| Galvanising report | Standard named, thickness readings, article list |
| Weld and NDT records | Procedure, welder qualification, test results where specified |
| Dimensional report | Against shop drawings and agreed tolerances |
Match heat numbers on the certificate to markings on the steel during inspection. For how inspection is done, see our pre-shipment inspection guide, and for how a factory’s capability is checked first, what a factory audit covers. The category overview is on our steel structure sourcing page.
5. Plan trial assembly and packing
For complex frames, ask whether a trial fit of key assemblies is feasible before packing, and have members packed in erection order with marks readable on each piece. Bundles are heavy, so plan the container load by weight, not volume: see container weight limits for building materials once published, and export packaging for building materials.
Mistakes that cause rework
- Leaving connection design unassigned.
- Starting fabrication on a quote drawing rather than approved shop drawings.
- Writing “galvanised” without a standard.
- Accepting certificates without matching heat numbers.
- Planning the container by volume only.
Frequently asked questions
Who is responsible for connection design on an imported steel structure?
It depends on your contract and local practice. Decide it in writing before quotes. In UK practice the steelwork contractor usually designs connections from information the engineer provides.
Which standard should I specify for galvanising?
Use the standard named in your project specification. ISO 1461 covers hot dip galvanizing of fabricated steel articles, and ASTM A123 is common in US specifications.
What should I approve before fabrication starts?
Shop drawings, the cutting list with grades, and the connection and surface-treatment notes.
How do I check that the steel matches its certificate?
Compare the heat numbers and grade on the mill certificate with the markings on the steel at inspection.
Related: Whole-project material sourcing